Zdobienie

M13 (NGC 6205) – The Stellar Metropolis

Zdobienie

M13 (NGC 6205) – The Stellar Metropolis

M13 – The Reference Point 

Messier 13 is the benchmark object. We compare every other northern globular cluster to it. Located 25,000 light-years away, it is bright enough (mag 5.8) to be seen with the naked eye under dark skies as a “fuzzy patch.” However, only astrophotography reveals its true nature—a dense ball comprising several hundred thousand stars.

Structure: “The Propeller”

Looking at my image, it’s worth noting a subtle detail known to cluster hunters. In the southwestern part of M13, there is a distinctive dark structure shaped like the letter “Y” or a three-bladed propeller (similar to the Mercedes logo).

  • This is not a hole in the cluster, but a lane of dark dust obscuring the glow of the stars behind it.

  • Capturing “The Propeller” is a test of your setup’s resolution and seeing quality, as it tends to blend into the core’s glare during longer exposures.

M13 - Cluster of Herkules
M13 – Cluster of Herkules

Density and Collisions

M13 spans about 145 light-years. The stars in its center are packed so tightly that if Earth were located inside M13, our sky would never know night—it would be filled with thousands of stars brighter than Venus. This density has consequences. Stellar collisions occur here, creating so-called Blue Stragglers—hot, blue stars that theoretically shouldn’t exist in such an old population but have been “reborn” through matter fusion with neighbors.

Historical Context: The Arecibo Message

M13 also holds cultural significance. It was the target of the famous 1974 radio message sent by the Arecibo telescope, containing information about humanity, DNA, and the Solar System. Why there? Because the high density of stars in the antenna’s beam provided the highest statistical chance that the signal would encounter a civilization. However, it will not arrive there for another 25,000 years.

Photographs taken on: March 2019.

Composition: APP (10 best frames and Flat and Dark + Bias frames)
Processing: GIMP v2.10.14 + add-ons (Linux)
Lights: 10 x 57[s], ISO-1600;

Comparative photo. Left shows new processing with a new method that I use today. Right, older, processed by the old method.


M13 – Gromada w Herkulesie / Hercules Cluster

Support my work on Ko-fi

Did this guide help you?

I create these guides and projects as a hobby. If I helped you save time or money, consider supporting my work with a coffee. It keeps the energy flowing for future projects.

Categories
Newest articles

iOptron CEM 25P

iOptron CEM 25P RA axle bearings replacement

iOptron CEM 25P RA axle bearings replacement. Instructions for how to replace faulty RA-axis bearings (6907) in the iOptron CEM 25P mount yourself. Eliminate friction and improve tracking accuracy. Do…

Support

Was description useful? Consider to support author, it prevents to post annoying ads for you. All you just could do is once a year, sponsor for me a coffee. The currency, amount, doesn’t matter to me. Matter to me, that you want!

Read

Similar Articles

SynScan controller firmware update

SynScan controller firmware update – NEQ6Pro

WARNING – the author of this manual accepts no responsibility, for any damages that may occur as a result of following this manual. All actions described in this manual are undertaken at your own risk. SynScan controller firmware update – Introduction   Starting from version 3.0, users can independently update the firmware of SynScan controllers for NEQ mounts. Simply download the latest software version from the Sky-Watcher website and perform the update following the instructions provided here. Requirements SynScan™ Hand Control of version 3.0 or later. Windows 8.1 or later An available RS-232C communication port on the PC RS232-USB hardware converter in case of missing DB9 COM port in your laptop / PC PC link cable that comes with the SynScan™ hand control DC power supply with 12~14V/1A output. Power plug should be 2.1mm diameter, tip positive.      Preparation for update Create a directory called SynScan, preferably on your C: drive. Visit the Support Page of the Sky-Watcher website at https://www.skywatcher.com/download/software/ Download and save two files, follow with example: Windows program: SynScan Firmware Loader, Version 3.5 – click with Download button. you’ll save a file with name: synscan_verXXXXXX_firmware_release.zip where XXXXXX – is a version nr Next download Firmware: SynScan V4/V5 Hand Controller For All GO-TO Mounts, Version 4.39.21 – click on Download button you’ll save a file with name: synscanfirmwareloader_verXX.zip where XX – is version nr Connecting devices Connect the USB-COM (RS232) adapter to the computer’s USB port.   Connect the male COM plug of the adapter to the female COM plug of the SynScan controller cable.   Connect the RJ-11 plug of the controller’s COM cable to the RJ-11 port on the controller. Ensure that the plug is securely inserted—you should hear a distinct “click” as the plug snaps firmly into place in the controller’s socket.   Connect the controller to the mount using the dedicated cable – RJ45 plug to the COM port on the mount. Ensure the cable is securely connected to both the controller and the mount for proper communication during operation. We now have the following connection setup – example:   Firmware update the SynScan™ Hand Control On the controller, simultaneously press and hold the buttons “0” and “8.” Turn on the mount’s power as shown in below photo. The controller will emit a “beep” sound during startup and then display the message “SynScan Update Ver….” as shown in the image. The controller has now been set to firmware update mode. This indicates that the device is ready for the next steps in the firmware update process. On your computer, run the Computer Manager and find the COM port which will be used for update. With this example it is COM5. Check the COM port number on your system. Open Computer Management and locate the COM port. To do this on a Windows system: Press Win + X and select Computer Management from the menu. In the Computer Management window, navigate to Device Manager. Expand the section labeled Ports (COM & LPT). Here, you will see a list of available COM ports along with their assigned numbers (e.g., COM1, COM2). With this example it is COM5. Run the SynScanFirmwareLoader.exe software on your PC. Once the program is launched, you should see a window SynScan Firmware Loader , make sure the “Auto-detect COM Port” checkbox has been unchecked. Set the COM port. Click the HC Version button. The program will attempt to connect to the controller and retrieve information about the hardware version, firmware, and the celestial object database. You will see the version numbers at the bottom of the Firmware Loader as shown on below picture. If the program is unable to communicate with the controller, enable the Auto-detect COM Port option and click the HC Version button again. If the Loader program cannot detect an available COM port, check the connection between the controller and the computer. Click Browse to select the SynScanVXXXX.ssf file in the SynScan folder. It is recommended to enable the – Enforce database update – option and then click the Update button to start the update procedure. This ensures that the entire database is refreshed during the update process, reducing the risk of any errors or omissions. The update status can be monitored under the Update and HC. Version buttons. Update Complete. Click on the HC. Version button and check if the controller has reported a new Firmware version. The update was fully successful. Close the Loader program and turn off mount power suppl. Turn the mount’s power back on and check whether the controller displays the new firmware version. Check if the mount and H.C. works properly. As you can see, the firmware update process for the SynScan V4 controller is not overly complicated, but it does require careful attention. It’s crucial to follow all the steps outlined in this guide in the correct sequence, with focus and precision. I hope the description provided could be at least somewhat helpful.   It’s worth mentioning that the mount performs excellently in the field when used with the PERUN II power bank.

Read more...