Zdobienie

StarStaX and Star Trails – Photo Stacking and Gap Filling

Zdobienie

StarStaX and Star Trails – Photo Stacking and Gap Filling

Why StarStaX?

In modern landscape astrophotography, creating Star Trails by taking hundreds of shorter exposures is preferred over a single, hours-long shot. This approach has a key practical advantage: if a flashlight shines into the lens, a car passes by, or the tripod gets bumped, you simply discard that single frame rather than losing the entire night’s work. To combine these frames into a final image, StarStaX is the go-to free software. It is lightweight, fast, and dedicated specifically to this task.

How It Works?

The “Lighten” Mode StarStaX does not sum up light in the traditional way (which would result in an overexposed, white image). It uses the “Lighten” blending mode. The software analyzes every pixel across all images and selects only the one with the highest brightness value for the final output.

  • This ensures bright stars “overwrite” the dark sky background.

  • Noise in the shadows does not accumulate, keeping the final image clean.

The Gap Problem and “Gap Filling”

There is always a tiny delay between shots (time for the camera to write the file to the card). As a result, after stacking, star trails might look like dashed lines (“beads on a string”). StarStaX solves this with the Gap Filling feature. The algorithm analyzes the end of a star trail on one frame and the beginning on the next, mathematically interpolating the missing segment. The result is perfectly smooth arcs, even if your camera has a slower buffer.

“Comet Mode” Option

An interesting addition is the Comet Mode. The software simulates a gradual fading of the star trail, adding dynamics and a sense of motion to the image, resembling a meteor shower or comets.

Creating Star Trails is one of the most spectacular astrophotography techniques. In this comprehensive step-by-step tutorial, you will learn how to stack a series of individual frames into one stunning image using the free StarStax software. This guide includes the essential step of RAW file conversion to a lossless 16-bit PNG format using RawTherapee, and it’s friendly for Linux users (as it uses free, multi-platform tools).

Capturing Star Trails in a photo is not to difficult task. There are several schools to do this. The Internet has many descriptions and videos on how to do this. I think I’ll never become a YouTuber, personally I prefer to create a document or simple instruction that describe the whole ho-to process in clear technical language and this was what it guide me during preparation this description.

Remember that each photo is different and the following examples, will not necessarily work for your photo light collection. My best practice is to always look for the optimal settings and processing solutions for each photo separately. It can be also your best practice.

English is not my native language. I wrote this description with my best I can, I will be grateful for any support by e-mail with information, where I made a mistake to correct it.

I do not consider myself as an expert with described subject. I think I still have a lot to learn and find a way, to get an better final effect than the one presented in the photo below.

Star Trails over Teide - Tenerife
Star Trails over Teide – Tenerife

Together we will go through with three main steps.

  1. Preparation of the source light frames, eg in the RawTherapee program. It can be any other program you like it to use or learn RawTherapee for self-discovery.
  2. Stacking the light frames together using the StarStax program,
  3. Complete the photo using the available functions in StarStax.

 

1. RawTherapee – RAW Conversion and Light Frame Preparation

StarStax version 0.71 cannot handle .RAW files. Before we join the light frames together, we have to convert the .RAW type of the collected light files, to the .PNG 16bit or TIFF 16bit type. It can’t be a type, e.g. JPG or other type, that generates quality losses. I’ve chosed the .PNG 16bit type. Lets go for actions.

Start the RawTherapee and go to the File Browser tab, to load light frames by clicking on the appropriate file folder.

RawTherapee - File Browser
RawTherapee – File Browser

Click on the first light frame and adjust its parameters (brightness, contrast, color saturation, exposure, etc.) to your preferences. The options available on the image processing tabs, are available for this purpose. Experiment to get to know them and learn how to use them.

RawTherapee - Tabs
RawTherapee – Tabs

Each processed photo has its own profile of changes. This profile should be copied and placed / pasted on the remaining photos in the queue, so that each photo has the same changes – the nature of the author of the processing. In the top preview bar, the first photo is highlighted with a colored frame – the active photo. Right-click on the active photo and select Processing profile operations → Copy from the context menu to copy the profile.

RawTherapee - Processing profile operations - Copy
RawTherapee – Processing profile operations – Copy

Now, we will apply the copied profile to the remaining photos. On the top photo preview bar, left-click any photo, press CTRL + A to select all photos. Then right-click on any photo and select Processing profile operations → Paste. The profile will be applied to all photos almost at once. Depending on the number of photos and the processing power of your computer, the change process may take a little longer.

RawTherapee - Processing profile operations - Paste
RawTherapee – Processing profile operations – Paste

The last step is to export the modified photos to the .PNG 16bit type. Select all photos in the same way as we did in the previous step (CTRL + A). Right-click on any photo and select Put to queue from the context menu.

RawTherapee - Put to queue
RawTherapee – Put to queue

On the left side of the program window, click on the Queue [..] tab to change the view to the export queue. Set Output Location to Save to folder to specify the destination directory where the .PNG output files will be saved. Set File Format to PNG (16-bit). Now click the OFF switch and change it to ON to start the photo export process.

RawTherapee - queue setup
RawTherapee – queue setup

Now is the time for coffee / tea / whatever you prefer. The photo export process will take a while. When it is finished, go to the next chapter → StarStax – photo submission and stacking.

2. StarStax – Loading Images and Star Trails Stacking

Run the program and load the files, in my case they are .PNG files exported by RawTherapee. Click on the icon under the File menu, a dialog box will appear with the selection of files.

StarStax - Menu File
StarStax – Menu File

Click on any file and press CTRL + A to select all photos. Click on Open.

StarStax - file list
StarStax – file list

On the right side of the screen, click the gear icon (Preferences…). There will be additional options that needs to be configured. On the Blending tab, in the Blending Mode area, click the drop-down list and select Gap Filing. You have to fill in any tiny gaps in the star trail, that may appear between individual photos. We leave the other options at the default settings.

StarStax - Gap Filling
StarStax – Gap Filling

Click on the Images tab, under View Interpolation, click on the drop-down list and set Smooth. Below is the Background slider, move it to the left. The options available on the General tab remain unchanged.

StarStax - Preferences
StarStax – Preferences

Click on the Start Processing icon.

StarStax - Start Processing
StarStax – Start Processing

The stacking process will take a while. You should be patient. Processing preview:

StarStax - stacking process
StarStax – stacking process

3. StarStax – Final Processing and Gap Filling

The result of the photo stacking processing is shown in the preview. Depending on the quality of the collected light frames, it may happen that the star trails are not a continuous line and contain many very short gaps. It is a good idea, to do an activity, to replace the missing light in these gaps. The Gap Filling function is used for this.

Enable the Show Threshold Overlay option. The trail of stars will be colored green. This is the mask that illustrates how the star trail detection algorithm works.

StarStax - Show Threshold Overlay
StarStax – Show Threshold Overlay

Zoom the photo to a size, where you can recognize the individual star trails. Move the center view to the position, where you can see a solid green color in the photo.

StarStax - Gap filling - continuous green
StarStax – Gap filling – continuous green

Grab the Threshold slider and move it to the right, until the solid color visible on the horizon disappears and remains only on the trail of stars. Do not pay attention to strong light sources. Their overexposure can be corrected in post-processing with photo processing programs (GIMP, Photoshop etc.).

You can set the fill level for gaps with the Amount slider. In my example, set it in the middle of scale worked. Experiment with the level to find the best match for you.

StarStax - Gap filling - Amount
StarStax – Gap filling – Amount

Now we have to save the final result with our photo. Click on Save As …

StarStax - Save As
StarStax – Save As

A .TIFF file is best for further processing. Click on Save and you’re done.

StarStax - File name
StarStax – File name

The final processing should be done with the program, which you like to edit photos. I like GIMP and RawTherapee.

Support my work on Ko-fi

Did this guide help you?

I create these guides and projects as a hobby. If I helped you save time or money, consider supporting my work with a coffee. It keeps the energy flowing for future projects.

Categories
Newest articles

iOptron CEM 25P

iOptron CEM 25P RA axle bearings replacement

iOptron CEM 25P RA axle bearings replacement. Instructions for how to replace faulty RA-axis bearings (6907) in the iOptron CEM 25P mount yourself. Eliminate friction and improve tracking accuracy. Do…

Support

Was description useful? Consider to support author, it prevents to post annoying ads for you. All you just could do is once a year, sponsor for me a coffee. The currency, amount, doesn’t matter to me. Matter to me, that you want!

Read

Similar Articles

SynScan controller firmware update

SynScan controller firmware update – NEQ6Pro

WARNING – the author of this manual accepts no responsibility, for any damages that may occur as a result of following this manual. All actions described in this manual are undertaken at your own risk. SynScan controller firmware update – Introduction   Starting from version 3.0, users can independently update the firmware of SynScan controllers for NEQ mounts. Simply download the latest software version from the Sky-Watcher website and perform the update following the instructions provided here. Requirements SynScan™ Hand Control of version 3.0 or later. Windows 8.1 or later An available RS-232C communication port on the PC RS232-USB hardware converter in case of missing DB9 COM port in your laptop / PC PC link cable that comes with the SynScan™ hand control DC power supply with 12~14V/1A output. Power plug should be 2.1mm diameter, tip positive.      Preparation for update Create a directory called SynScan, preferably on your C: drive. Visit the Support Page of the Sky-Watcher website at https://www.skywatcher.com/download/software/ Download and save two files, follow with example: Windows program: SynScan Firmware Loader, Version 3.5 – click with Download button. you’ll save a file with name: synscan_verXXXXXX_firmware_release.zip where XXXXXX – is a version nr Next download Firmware: SynScan V4/V5 Hand Controller For All GO-TO Mounts, Version 4.39.21 – click on Download button you’ll save a file with name: synscanfirmwareloader_verXX.zip where XX – is version nr Connecting devices Connect the USB-COM (RS232) adapter to the computer’s USB port.   Connect the male COM plug of the adapter to the female COM plug of the SynScan controller cable.   Connect the RJ-11 plug of the controller’s COM cable to the RJ-11 port on the controller. Ensure that the plug is securely inserted—you should hear a distinct “click” as the plug snaps firmly into place in the controller’s socket.   Connect the controller to the mount using the dedicated cable – RJ45 plug to the COM port on the mount. Ensure the cable is securely connected to both the controller and the mount for proper communication during operation. We now have the following connection setup – example:   Firmware update the SynScan™ Hand Control On the controller, simultaneously press and hold the buttons “0” and “8.” Turn on the mount’s power as shown in below photo. The controller will emit a “beep” sound during startup and then display the message “SynScan Update Ver….” as shown in the image. The controller has now been set to firmware update mode. This indicates that the device is ready for the next steps in the firmware update process. On your computer, run the Computer Manager and find the COM port which will be used for update. With this example it is COM5. Check the COM port number on your system. Open Computer Management and locate the COM port. To do this on a Windows system: Press Win + X and select Computer Management from the menu. In the Computer Management window, navigate to Device Manager. Expand the section labeled Ports (COM & LPT). Here, you will see a list of available COM ports along with their assigned numbers (e.g., COM1, COM2). With this example it is COM5. Run the SynScanFirmwareLoader.exe software on your PC. Once the program is launched, you should see a window SynScan Firmware Loader , make sure the “Auto-detect COM Port” checkbox has been unchecked. Set the COM port. Click the HC Version button. The program will attempt to connect to the controller and retrieve information about the hardware version, firmware, and the celestial object database. You will see the version numbers at the bottom of the Firmware Loader as shown on below picture. If the program is unable to communicate with the controller, enable the Auto-detect COM Port option and click the HC Version button again. If the Loader program cannot detect an available COM port, check the connection between the controller and the computer. Click Browse to select the SynScanVXXXX.ssf file in the SynScan folder. It is recommended to enable the – Enforce database update – option and then click the Update button to start the update procedure. This ensures that the entire database is refreshed during the update process, reducing the risk of any errors or omissions. The update status can be monitored under the Update and HC. Version buttons. Update Complete. Click on the HC. Version button and check if the controller has reported a new Firmware version. The update was fully successful. Close the Loader program and turn off mount power suppl. Turn the mount’s power back on and check whether the controller displays the new firmware version. Check if the mount and H.C. works properly. As you can see, the firmware update process for the SynScan V4 controller is not overly complicated, but it does require careful attention. It’s crucial to follow all the steps outlined in this guide in the correct sequence, with focus and precision. I hope the description provided could be at least somewhat helpful.   It’s worth mentioning that the mount performs excellently in the field when used with the PERUN II power bank.

Read more...